PT-2000PVE is a stand along plasma system specifically designed to treat the outside surfaces of the catheters, mandrels, plastic tubes or the like. PT-2000PVE/c is used to treat a distal portion of coiled catheter.
The system is comprised of High Voltage Plasma Generator with flat electrode connected to PLC driven Power Supply with Touch Screen Control Panel. During the operation, the system constantly checks plasma current, gas flow and pressure. If any of the parameters fluctuates beyond specified limit, alarm goes on. Alarm set points and trip delays are programmable and password protected.
The system operates in ambient air at atmospheric pressure and utilizes compressed ARGON or HELIUM to activate the discharge. Special gases or mixtures may be used to create a discharge with specific properties. Plasma treatment zone has specific dimensions defined by a customer.
PLC stores up to ten sets of optimized plasma parameters dedicated to specific treatment processes (recipes). A required recipe can then be easily selected from a list when changing, for example, from treatment of one specific part to another. The system records original setup parameters, all changes in the corresponding recipes, and the alarms. Log file can be downloaded to a regular computer via ethernet connection.
Standard electrode configuration - PT-2000DBD flat 1x1’
Plasma Potential - 10-30KV
Plasma Frequency - 10-30KHz
Primary Plasma Gases - Argon, Helium
Typical Gas Consumption (scfh) - 10-20 , 30 MAX
Typical Gas Pressure (PSI) - 15-25 , 60 MAX
Typical Power Consumption (W) - 100
Typical Processing Speed (parts/min) - 1-10
MAX Part OD (mm) - 6
Length of Treatment (cm) - 1-100
Dimensions (in) Power Supply High Voltage generator Catheter holder - 24x24x9 6x6x6 12x12x60
Weight (lb.) - 50-75
Power requirement - 120/250V, 60/50 Hz, 3 A
Operating Environment - Temperature 35-105 oF, Humidity 90% max, non-condensing
related products
Quisque tincidunt enim mollis augue sollicitudin quis cursus risus vehicula. Ut faucibus convallis dapibus. Suspendisse volutpat.
PT-2000
PT-2000:
Tri-Star Technologies presents the PT-2000, a turnkey system that dramatically increases the surface energy of any non conductive material including...
PT-2000BSA is a Low Current Surface Plasma Treatment System operating at Atmospheric Pressure and designed to significantly improve surface wettability...
Tri-Star Technologies presents the PT-2000, a turnkey system that dramatically increases the surface energy of any non conductive material including...
PT-2000BSA is a Low Current Surface Plasma Treatment System operating at Atmospheric Pressure and designed to significantly improve surface wettability...
Tri-Star Technologies presents the PT-2000, a turnkey system that dramatically increases the surface energy of any non conductive material including...
PT-2000BSA is a Low Current Surface Plasma Treatment System operating at Atmospheric Pressure and designed to significantly improve surface wettability...
We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. By clicking “Accept”, you consent to the use of ALL the cookies. Read MoreAccept
This website uses cookies to improve your experience while you navigate through the website. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the ...
Necessary cookies are absolutely essential for the website to function properly. These cookies ensure basic functionalities and security features of the website, anonymously.
Cookie
Duration
Description
cookielawinfo-checkbox-analytics
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics".
cookielawinfo-checkbox-functional
11 months
The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional".
cookielawinfo-checkbox-necessary
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary".
cookielawinfo-checkbox-others
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other.
cookielawinfo-checkbox-performance
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance".
viewed_cookie_policy
11 months
The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data.
Functional cookies help to perform certain functionalities like sharing the content of the website on social media platforms, collect feedbacks, and other third-party features.
Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.
Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics the number of visitors, bounce rate, traffic source, etc.
Advertisement cookies are used to provide visitors with relevant ads and marketing campaigns. These cookies track visitors across websites and collect information to provide customized ads.